See also: Tadano crane manuals
Error Number |
Fault |
1 |
Fault in the upper unit's speed-sensor input (Main sensor fault) |
2 |
Fault in the lower unit's speed-sensor input (Sub-sensor fault) |
3 |
Fault in the upper unit's speed-sensor input Main sensor fault (with the change lever in N) |
4 |
Fault in the outrigger detection unit input (F*L) |
5 |
Fault in the outrigger detection unit input (F*R) |
6 |
Fault in the outrigger detection unit input (R*L) |
7 |
Fault in the outrigger detection unit input (R*R) |
8 |
Fault in the torque converter pressure input |
10 |
Fault in the upper unit E - PROM |
15 |
Fault in the upper unit RAM |
16 |
Fault in the lower unit RAM |
17 |
Fault in the lower unit A/D converter |
18 |
Fault in the upper unit ROM |
19 |
Fault in the lower unit ROM |
24 |
Fault in the upper unit's transmission signal input |
25 |
No transmission signal input to the upper unit |
27 |
Fault in the upper unit's steering input |
30 |
Fault in the upper unit's speed-sensor input (Main sensor fault; 70 km/h or higher) |
31 |
Lack of signal exchange between the upper unit and the lower unit (Broken transfer line) |
32 |
Fault communication between the upper unit and the lower unit |
33 |
No transmission from the AML to the upper unit |
34 |
Fault in the speed data RAM |
40 |
Fault in the hydraulic suspension system vehicle height detector (F*L) |
41 |
Fault in the hydraulic suspension system vehicle height detector (F*R) |
42 |
Fault in the hydraulic suspension system vehicle height detector (R*L) |
43 |
Fault in the hydraulic suspension system vehicle height detector (R*R) |
50 |
Out of range during outrigger zero adjustment (F*L) |
51 |
Out of range during outrigger zero adjustment (F*R) |
52 |
Out of range during outrigger zero adjustment (R*L) |
53 |
Out of range during outrigger zero adjustment (R*R) |
55 |
Out of range during outrigger span adjustment (F*L) |
56 |
Out of range during outrigger zero adjustment (F*R) |
57 |
Out of range during outrigger zero adjustment (R*L) |
58 |
Out of range during outrigger zero adjustment (R*R) |
70 |
Fault in the outrigger detection unit input (disconnection) (F*L) |
71 |
Fault in the outrigger detection unit input (disconnection) (F*R) |
72 |
Fault in the outrigger detection unit input (disconnection) (R*L) |
73 |
Fault in the outrigger detection unit input (disconnection) (R*R) |
80 |
Instability In the lower unit relay output |
81 |
Fault in the lower unit relay output (output OFF, monitor ON) |
84 |
Fault in the lower unit relay output (output ON, monitor OFF) |
82 |
Fault in the lower unit relay output (output OFF, monitor ON) |
85 |
Fault in the lower unit relay output (output ON, monitor OFF) |
83 |
Fault in the lower unit relay output (output OFF, monitor ON) |
86 |
Fault in the lower unit relay output (output ON, monitor OFF) |
87 |
Fault in the lower unit relay output (output OFF, monitor ON) |
88 |
Fault in the lower unit relay output (output ON, monitor OFF) |
8C |
Fault in the lower unit relay output (output OFF, monitor ON) |
8d |
Fault in the lower unit relay output (output ON, monitor OFF) |
If problems occur outside of the transmitter units (e.q., upper electric circuit switch faults, broken wire lines between upper electric circuit switches and upper transmitter unit, lower electric circuit solenoid valve faults, broken wire lines between lower electric circuit solenoid valves and lower transmitter unit), no error number will be displayed.
(However, error number 1, 2, 3, 4, 5, 6, 7, 8, 24, 25, 30, 31, 32, 33, 40, 41, 42, 43, 50, 51, 52, 53, 55, 56, 57, 58, 70, 71, 72, 73, 80, 81, 82, 83, 84, 85, 86, 87, 88, 8C, and 8d will be displayed even when problems that are not related to the transmitter units occur.)
Display Number |
Item |
Content |
77 |
Outrigger adjustment mode message |
If the outrigger zero/span adjustment switch is turned on/off three times within three seconds, [77] will be displayed to indicate that outrigger adjustment mode is currently in effect. After that, the zero adjustment shown below will begin. |
0 0 |
Outrigger zero adjustment complete message |
If outrigger zero span adjustment is completed after the outrigger zero/span adjustment switch is turned on/off once, [00] will be displayed. |
99 |
Outrigger span adjustment complete message |
If outrigger span adjustment is completed after the outrigger zero/span adjustment switch is turned on/off once following outrigger zero adjustment, [99] will be displayed and than disappear |
1 0 X X |
Type TR-100M-1 (X-type outrigger) Version XX |
This message appears when the power is on or the system check switch is ON; it then disappears. |
1 1 X X |
Type TR-100M-1 (H-type outrigger) Version XX |
|
2 7 X X |
Type TR-250M-6 (X-type outrigger) Version XX |
|
2 8 X X |
Type TR-250M-6 (H-type outrigger) Version XX |
|
3 6 X X |
Type TR-350M-3 (X-type outrigger) Version XX |
|
5 1 X X |
Type TR-500M-3 (X-type outrigger) Version XX |
|
5 2 X X |
Type TR-500M-3 (H-type outrigger) Version XX |
|
2 U X X |
Type TR-200EX-2 and TR-250EX-2 Version XX |
|
4 U X X |
Type TR-400EX-3 and TR-500EX-3 Version XX |
|
2 E X X |
Type TR-250EX-3 Version XX |
|
3 E X X |
Type TR-300EX-2 and TR-300EX-3 Version XX |
|
3 A X X |
Type TR-350XL-3 Version XX |
|
4 A X X |
Type TR-500XL-3 and TR-600XL-3 Version XX |